Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Notice: Unexpected clearActionName after getActionName already called in /var/www/html/w/includes/Context/RequestContext.php on line 321
Data for: Distance calibration via Newton's rings in yttrium lithium fluoride whispering gallery mode resonators - MaRDI portal

Deprecated: Use of MediaWiki\Skin\SkinTemplate::injectLegacyMenusIntoPersonalTools was deprecated in Please make sure Skin option menus contains `user-menu` (and possibly `notifications`, `user-interface-preferences`, `user-page`) 1.46. [Called from MediaWiki\Skin\SkinTemplate::getPortletsTemplateData in /var/www/html/w/includes/Skin/SkinTemplate.php at line 691] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of MediaWiki\Skin\BaseTemplate::getPersonalTools was deprecated in 1.46 Call $this->getSkin()->getPersonalToolsForMakeListItem instead (T422975). [Called from Skins\Chameleon\Components\NavbarHorizontal\PersonalTools::getHtml in /var/www/html/w/skins/chameleon/src/Components/NavbarHorizontal/PersonalTools.php at line 66] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of QuickTemplate::(get/html/text/haveData) with parameter `personal_urls` was deprecated in MediaWiki Use content_navigation instead. [Called from MediaWiki\Skin\QuickTemplate::get in /var/www/html/w/includes/Skin/QuickTemplate.php at line 131] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Data for: Distance calibration via Newton's rings in yttrium lithium fluoride whispering gallery mode resonators

From MaRDI portal
(Redirected from Dataset:6705645)



DOI10.5281/zenodo.7134104Zenodo7134104MaRDI QIDQ6705645

Dataset published at Zenodo repository.

Author name not available (Why is that?)

Publication date: 16 November 2022

Copyright license: No records found.



Dataset of Newtons rings images captured through the short face of a trapezoidal prism with a whispering gallery mode resonator positioned behind the prism. Each file corresponds to an applied piezo voltage over a voltage sweep decreasing in voltage steps of 0.1V (file names multiplied by 10). Both image data and oscilloscope data are included.Runs 18-27 42-53 use a green (530+-2nm) filter and Runs 28-41 use a red (670+-2 nm) filter. crop-images.ipynb is used to process the raw images located in FullDataset.zip into grayscale jpg images, these processed images are then fed into Ringanalyzer-simplified.ipynb that calls from RingAnalyzer.py to convert the 2-D images to a signal-radius plot based onfits of an elliptical pattern, finding ellipticity, centroid, and rotation angle. process_run_logfit.m ultilizesthe 1-D signal plot used to convert the piezo voltages to coupler distances, then a Lorentz fit is applied to the data from the oscilloscope - using lorentzfit.m to perform the fit.Thefinalresultisa log plot of the coupling linewidth as a function of distance. The data for resultant plots can be found in ProcessedDataset.zip and can be plotted by plot_processed_run.m. Figure 3.zipcontains just the data subset used to generate Figure 3, with fig3.m to generate the figure.






This page was built for dataset: Data for: Distance calibration via Newton's rings in yttrium lithium fluoride whispering gallery mode resonators