Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
Generalized availability measures for a two-unit warm standby system - MaRDI portal

Generalized availability measures for a two-unit warm standby system (Q1060677)

From MaRDI portal





scientific article; zbMATH DE number 3908135
Language Label Description Also known as
English
Generalized availability measures for a two-unit warm standby system
scientific article; zbMATH DE number 3908135

    Statements

    Generalized availability measures for a two-unit warm standby system (English)
    0 references
    0 references
    0 references
    0 references
    1985
    0 references
    This paper obtains generalized availability measures, e.g. interval reliability, joint interval reliability, joint availability, etc., for a two-unit warm standby repairable system. The regenerative point technique of a Markov Renewal Process has been employed to obtain these measures. Some particular cases are also considered. The technique used in this paper is straight forward and easy to apply.
    0 references
    generalized availability measures
    0 references
    joint interval reliability
    0 references
    two-unit warm standby repairable system
    0 references
    regenerative point technique
    0 references