RBF nonsmooth control method for vibration of building structure with actuator failure (Q1693777)
From MaRDI portal
| This is the item page for this Wikibase entity, intended for internal use and editing purposes. Please use this page instead for the normal view: RBF nonsmooth control method for vibration of building structure with actuator failure |
scientific article; zbMATH DE number 6833039
| Language | Label | Description | Also known as |
|---|---|---|---|
| English | RBF nonsmooth control method for vibration of building structure with actuator failure |
scientific article; zbMATH DE number 6833039 |
Statements
RBF nonsmooth control method for vibration of building structure with actuator failure (English)
0 references
31 January 2018
0 references
Summary: In order to accommodate the actuator failure, the finite-time stable nonsmooth control method with RBF neural network is used to suppress the structural vibration. The traditional designed control methods neglect influence of actuator failure in structural vibration. By Lyapunov's stability theory, the designed control method is demonstrated to suppress the building structural vibration with actuator failure. Finally, there are some examples to numerically simulate the three-layer building structure which is affected by El Centro seismic wave. Control effect of nonsmooth control is compared with no control and LQR control. The simulation results demonstrate that the designed control method is great for vibration of building structure with actuator failure and great antiseismic effect.
0 references
RBF nonsmooth control method
0 references
vibration of building structure
0 references
0 references