Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
A hybrid wavelet-based method for the peak detection of photoplethysmography signals - MaRDI portal

A hybrid wavelet-based method for the peak detection of photoplethysmography signals (Q1784151)

From MaRDI portal





scientific article; zbMATH DE number 6943948
Language Label Description Also known as
English
A hybrid wavelet-based method for the peak detection of photoplethysmography signals
scientific article; zbMATH DE number 6943948

    Statements

    A hybrid wavelet-based method for the peak detection of photoplethysmography signals (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    26 September 2018
    0 references
    Summary: The noninvasive peripheral oxygen saturation (SpO) and the pulse rate can be extracted from photoplethysmography (PPG) signals. However, the accuracy of the extraction is directly affected by the quality of the signal obtained and the peak of the signal identified; therefore, a hybrid wavelet-based method is proposed in this study. Firstly, we suppressed the partial motion artifacts and corrected the baseline drift by using a wavelet method based on the principle of wavelet multiresolution. And then, we designed a quadratic spline wavelet modulus maximum algorithm to identify the PPG peaks automatically. To evaluate this hybrid method, a reflective pulse oximeter was used to acquire ten subjects' PPG signals under sitting, raising hand, and gently walking postures, and the peak recognition results on the raw signal and on the corrected signal were compared, respectively. The results showed that the hybrid method not only corrected the morphologies of the signal well but also optimized the peaks identification quality, subsequently elevating the measurement accuracy of SpO and the pulse rate. As a result, our hybrid wavelet-based method profoundly optimized the evaluation of respiratory function and heart rate variability analysis.
    0 references
    hybrid wavelet-based method
    0 references
    peak detection
    0 references
    photoplethysmography signals
    0 references
    noninvasive peripheral oxygen saturation
    0 references
    pulse rate
    0 references

    Identifiers