    A 13-dimensional differential system is numerically studied describing an electric power system. Different types of bifurcations have been found including saddle-node bifurcation of periodic orbits which explains the voltage collapse in the system.
    0 references
    electric power system
    0 references
    simulation
    0 references
    bifurcation
    0 references
    saddle-node
    0 references