Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
In vivo determination of Young's modulus for the human cornea - MaRDI portal

In vivo determination of Young's modulus for the human cornea (Q1820715)

From MaRDI portal





scientific article; zbMATH DE number 3995494
Language Label Description Also known as
English
In vivo determination of Young's modulus for the human cornea
scientific article; zbMATH DE number 3995494

    Statements

    In vivo determination of Young's modulus for the human cornea (English)
    0 references
    0 references
    0 references
    1987
    0 references
    The present paper describes a calculation technique to determine a value of Young's modulus for the cornea when the intraocular pressure, the shape of the cornea and the thickness variation along the cornea are known from in vivo measurements. Twenty-eight persons were examined in both eyes and a mean value of Young's modulus for the cornea was calculated to \(2.45\times 10^ 4\pm 0.57\times 10^ 4N/m^ 2\) (S.D.).