Influence of control valve delay and dead zone on the stability of a simple hydraulic positioning system (Q1958819)

From MaRDI portal





scientific article; zbMATH DE number 5793739
Language Label Description Also known as
English
Influence of control valve delay and dead zone on the stability of a simple hydraulic positioning system
scientific article; zbMATH DE number 5793739

    Statements

    Influence of control valve delay and dead zone on the stability of a simple hydraulic positioning system (English)
    0 references
    0 references
    0 references
    0 references
    30 September 2010
    0 references
    Summary: This paper deals with the PI control of a highly simplified dynamic model of a hydraulic cylinder. It is assumed that the hydraulic fluid is incompressible and that the pump provides constant flow rates, which results in the possibility of velocity control. Two types of anomalies are taken into account: (a) the time delay due to the controller computations and the internal pressure dynamics and (b) the dead zone of the controller valve. This results in a nonlinear system described by a piecewise linear discontinuous map. The nonlinear behavior of the system is explored and the practically globally stable parameter domains are identified.
    0 references
    PI control
    0 references
    hydraulic cylinder
    0 references
    hydraulic fluid
    0 references
    velocity control
    0 references
    nonlinear system
    0 references
    piecewise linear discontinuous map
    0 references
    practically globally stable parameter domains
    0 references