Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
A rigid motion artifact reduction method for CT based on blind deconvolution - MaRDI portal

A rigid motion artifact reduction method for CT based on blind deconvolution (Q2005552)

From MaRDI portal





scientific article; zbMATH DE number 7257775
Language Label Description Also known as
English
A rigid motion artifact reduction method for CT based on blind deconvolution
scientific article; zbMATH DE number 7257775

    Statements

    A rigid motion artifact reduction method for CT based on blind deconvolution (English)
    0 references
    0 references
    0 references
    0 references
    8 October 2020
    0 references
    Summary: In computed tomography (CT), artifacts due to patient rigid motion often significantly degrade image quality. This paper suggests a method based on iterative blind deconvolution to eliminate motion artifacts. The proposed method alternately reconstructs the image and reduces motion artifacts in an iterative scheme until the difference measure between two successive iterations is smaller than a threshold. In this iterative process, Richardson-Lucy (RL) deconvolution with spatially adaptive total variation (SATV) regularization is inserted into the iterative process of the ordered subsets expectation maximization (OSEM) reconstruction algorithm. The proposed method is evaluated on a numerical phantom, a head phantom, and patient scan. The reconstructed images indicate that the proposed method can reduce motion artifacts and provide high-quality images. Quantitative evaluations also show the proposed method yielded an appreciable improvement on all metrics, reducing root-mean-square error (RMSE) by about 30\% and increasing Pearson correlation coefficient (CC) and mean structural similarity (MSSIM) by about 15\% and 20\%, respectively, compared to the RL-OSEM method. Furthermore, the proposed method only needs measured raw data and no additional measurements are needed. Compared with the previous work, it can be applied to any scanning mode and can realize six degrees of freedom motion artifact reduction, so the artifact reduction effect is better in clinical experiments.
    0 references
    computed tomography (CT)
    0 references
    iterative blind deconvolution
    0 references
    motion artifacts
    0 references
    Richardson-Lucy (RL) deconvolution
    0 references
    spatially adaptive total variation (SATV) regularization
    0 references

    Identifiers