Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
Gabor-based anisotropic diffusion with lattice Boltzmann method for medical ultrasound despeckling - MaRDI portal

Deprecated: Use of MediaWiki\Skin\SkinTemplate::injectLegacyMenusIntoPersonalTools was deprecated in Please make sure Skin option menus contains `user-menu` (and possibly `notifications`, `user-interface-preferences`, `user-page`) 1.46. [Called from MediaWiki\Skin\SkinTemplate::getPortletsTemplateData in /var/www/html/w/includes/Skin/SkinTemplate.php at line 691] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of QuickTemplate::(get/html/text/haveData) with parameter `personal_urls` was deprecated in MediaWiki Use content_navigation instead. [Called from MediaWiki\Skin\QuickTemplate::get in /var/www/html/w/includes/Skin/QuickTemplate.php at line 131] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Gabor-based anisotropic diffusion with lattice Boltzmann method for medical ultrasound despeckling (Q2045558)

From MaRDI portal





scientific article; zbMATH DE number 7381723
Language Label Description Also known as
English
Gabor-based anisotropic diffusion with lattice Boltzmann method for medical ultrasound despeckling
scientific article; zbMATH DE number 7381723

    Statements

    Gabor-based anisotropic diffusion with lattice Boltzmann method for medical ultrasound despeckling (English)
    0 references
    0 references
    13 August 2021
    0 references
    This paper proposes a despeckling approach for medical ultrasound images. This Gabor-based anisotropic diffusion coupled with the lattice Boltzmann method (GAD-LBM) uses the lattice Boltzmann method to quickly solve the partial differential equation of an anisotropic diffusion model embedded with the Gabor edge detector. In numerical experiments on synthetic and clinical ultrasound images, GAD-LBM was superior to nine other methods in speckle suppression and detail preservation. It was also faster than the GAD method with a finite difference PDE solver, by factors between 20 and 90.