Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
Automatic detection and quantification of WBCs and RBCs using iterative structured circle detection algorithm - MaRDI portal

Automatic detection and quantification of WBCs and RBCs using iterative structured circle detection algorithm (Q2262732)

From MaRDI portal
scientific article
Language Label Description Also known as
English
Automatic detection and quantification of WBCs and RBCs using iterative structured circle detection algorithm
scientific article

    Statements

    Automatic detection and quantification of WBCs and RBCs using iterative structured circle detection algorithm (English)
    0 references
    0 references
    0 references
    0 references
    16 March 2015
    0 references
    Summary: Segmentation and counting of blood cells are considered as an important step that helps to extract features to diagnose some specific diseases like malaria or leukemia. The manual counting of white blood cells (WBCs) and red blood cells (RBCs) in microscopic images is an extremely tedious, time consuming, and inaccurate process. Automatic analysis will allow hematologist experts to perform faster and more accurately. The proposed method uses an iterative structured circle detection algorithm for the segmentation and counting of WBCs and RBCs. The separation of WBCs from RBCs was achieved by thresholding, and specific preprocessing steps were developed for each cell type. Counting was performed for each image using the proposed method based on modified circle detection, which automatically counted the cells. Several modifications were made to the basic (RCD) algorithm to solve the initialization problem, detecting irregular circles (cells), selecting the optimal circle from the candidate circles, determining the number of iterations in a fully dynamic way to enhance algorithm detection, and running time. The validation method used to determine segmentation accuracy was a quantitative analysis that included Precision, Recall, and \(F\)-measurement tests. The average accuracy of the proposed method was 95.3\% for RBCs and 98.4\% for WBCs.
    0 references
    white and red blood cell detection and quantification
    0 references
    iterative structured circle detection algorithm
    0 references

    Identifiers