Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
Design and construction of pneumatic transfer system controller unit for Ghana MNSR - MaRDI portal

Deprecated: Use of MediaWiki\Skin\SkinTemplate::injectLegacyMenusIntoPersonalTools was deprecated in Please make sure Skin option menus contains `user-menu` (and possibly `notifications`, `user-interface-preferences`, `user-page`) 1.46. [Called from MediaWiki\Skin\SkinTemplate::getPortletsTemplateData in /var/www/html/w/includes/Skin/SkinTemplate.php at line 691] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of MediaWiki\Skin\BaseTemplate::getPersonalTools was deprecated in 1.46 Call $this->getSkin()->getPersonalToolsForMakeListItem instead (T422975). [Called from Skins\Chameleon\Components\NavbarHorizontal\PersonalTools::getHtml in /var/www/html/w/skins/chameleon/src/Components/NavbarHorizontal/PersonalTools.php at line 66] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of QuickTemplate::(get/html/text/haveData) with parameter `personal_urls` was deprecated in MediaWiki Use content_navigation instead. [Called from MediaWiki\Skin\QuickTemplate::get in /var/www/html/w/includes/Skin/QuickTemplate.php at line 131] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Design and construction of pneumatic transfer system controller unit for Ghana MNSR (Q2303396)

From MaRDI portal





scientific article
Language Label Description Also known as
English
Design and construction of pneumatic transfer system controller unit for Ghana MNSR
scientific article

    Statements

    Design and construction of pneumatic transfer system controller unit for Ghana MNSR (English)
    0 references
    0 references
    0 references
    0 references
    3 March 2020
    0 references
    Summary: Pneumatic transfer system (PTS) is an auxiliary system of Ghana Research Reactor-1 (GHARR-1) used to transfer sample capsule in and out of the reactor irradiation sites. The PTS' controller unit design and construction were carried out because the original transfer system was not designed to operate in cyclic NAA. To address these situations, a programmable logic controller (PLC) has been used to design and construct a control unit to facilitate a cyclic neutron activation analysis (CNAA) application for GHARR-1. The design has been simulated successfully using a LOGO soft comfort software, version 8. The constructed control unit has been tested experimentally using 220 AC volts electric bulbs to represent solenoid valves. The results show that the sample-IN and sample-OUT bulbs come ON and go OFF to represent the solenoid valves opening and closing for sample transfer. The study has shown that the computer based PLC controller unit for PTS is capable of facilitating both cyclic and conventional NAA application for the GHARR-1.
    0 references
    Ghana Research Reactor-1
    0 references
    pneumatic transfer system controller
    0 references
    Ghana MNSR
    0 references

    Identifiers