Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
Research on dual-carrier pulse-train-controlled buck converter - MaRDI portal

Research on dual-carrier pulse-train-controlled buck converter (Q2303402)

From MaRDI portal
scientific article
Language Label Description Also known as
English
Research on dual-carrier pulse-train-controlled buck converter
scientific article

    Statements

    Research on dual-carrier pulse-train-controlled buck converter (English)
    0 references
    0 references
    0 references
    3 March 2020
    0 references
    Summary: In order to solve the low-frequency oscillation of pulse-train- (PT-) controlled switching converter operating in a continuous conduction mode (CCM), a dual-carrier pulse-train (DCPT) control technique is proposed in this paper. With the CCM buck converter as an example, the operational principle, pulse control law, and output voltage ripple of the DCPT-controlled converter are studied. The experimental results are provided to verify the theoretical analysis and simulation results. Compared with the PT-controlled converter, the DCPT-controlled CCM buck converter enjoys much better operating characteristics and smaller output voltage ripple.
    0 references
    pulse-train-controlled switching converter
    0 references
    dual-carrier pulse-train control
    0 references