Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
Energy and exergy analysis for improving the energy performance of air-cooled liquid chillers by different condensing-coil configurations - MaRDI portal

Deprecated: Use of MediaWiki\Skin\SkinTemplate::injectLegacyMenusIntoPersonalTools was deprecated in Please make sure Skin option menus contains `user-menu` (and possibly `notifications`, `user-interface-preferences`, `user-page`) 1.46. [Called from MediaWiki\Skin\SkinTemplate::getPortletsTemplateData in /var/www/html/w/includes/Skin/SkinTemplate.php at line 691] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of MediaWiki\Skin\BaseTemplate::getPersonalTools was deprecated in 1.46 Call $this->getSkin()->getPersonalToolsForMakeListItem instead (T422975). [Called from Skins\Chameleon\Components\NavbarHorizontal\PersonalTools::getHtml in /var/www/html/w/skins/chameleon/src/Components/NavbarHorizontal/PersonalTools.php at line 66] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of QuickTemplate::(get/html/text/haveData) with parameter `personal_urls` was deprecated in MediaWiki Use content_navigation instead. [Called from MediaWiki\Skin\QuickTemplate::get in /var/www/html/w/includes/Skin/QuickTemplate.php at line 131] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Energy and exergy analysis for improving the energy performance of air-cooled liquid chillers by different condensing-coil configurations (Q406020)

From MaRDI portal





scientific article; zbMATH DE number 6340974
Language Label Description Also known as
English
Energy and exergy analysis for improving the energy performance of air-cooled liquid chillers by different condensing-coil configurations
scientific article; zbMATH DE number 6340974

    Statements

    Energy and exergy analysis for improving the energy performance of air-cooled liquid chillers by different condensing-coil configurations (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    8 September 2014
    0 references
    Summary: This study constructed a parameter analysis for improving the energy performance of air-cooled water chillers by altering the angle configuration of the condenser coils. The mathematical models for energy and exergy analyses of the individual components and overall system of air-cooled water chillers are presented. This study investigated the potential enhancement of performance efficiency in air-cooled chillers and the energy conversion efficiency of each component, in order to determine how the angle configuration of condenser coils influences chiller performance. This study found that the overall performance of an air-cooled chiller could be improved by approximately 3.4\%, and the total irreversibility could be reduced by approximately 2.7\%. With each 1\% increase in average wind speed over the condenser coils, the overall performance of an air-cooled chiller was found to be enhanced by approximately 0.43\%, and its total irreversibility was reduced by approximately 0.35\%. The results of this study can be effectively applied to air-cooled condenser units, and can provide an important basis of reference for developing and enhancing the energy efficiency of air-cooled chillers.
    0 references
    air-cooled liquid chiller
    0 references
    parameter analysis
    0 references
    exergy analysis
    0 references

    Identifiers