Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
Supplementary data for "Armored with skin and bone: A combined histological and µCT study of the exceptional integument of the Antsingy leaf chameleon Brookesia perarmata (Angel, 1933)" - MaRDI portal

Supplementary data for "Armored with skin and bone: A combined histological and µCT study of the exceptional integument of the Antsingy leaf chameleon Brookesia perarmata (Angel, 1933)" (Q6690050)

From MaRDI portal





Dataset published at Zenodo repository.
Language Label Description Also known as
English
Supplementary data for "Armored with skin and bone: A combined histological and µCT study of the exceptional integument of the Antsingy leaf chameleon Brookesia perarmata (Angel, 1933)"
Dataset published at Zenodo repository.

    Statements

    0 references
    This project contains the supplementary CT-scans of the whole body and a lateral flank integumentary armor of Brookesia perarmata(Angel, 1933) (Squamata: Iguania: Chamaeleonidae) belonging to the following publication: Schucht P, Rhr PT, Geier B, Glaw F M LAmbertz (2020): Armored with skin and bone: A combined histological and CT study of the exceptional integument of the Antsingy leaf chameleon Brookesia perarmata (Angel, 1933). Journal of Morphology. doi:10.1002/jmor.21135. Whole body scan: specimen:ZSM 17/2006, Zoologische Staatssammlung Mnchen machine:phoenix nanotom m (GE Measurement Control) scan settings: tube voltage = 110 kV ube current = 70 A target = tungsten no filter total sample rotation = 360 angular step size = 0.24 exposure time = 750 ms binning = 1 averaging = 4 voxel size = 37.8 m filename:Schucht_B_perarmata_whole.tif Lateral flank integumentary armor scan: specimen:ZSM 862/2000, Zoologische Staatssammlung Mnchen machine:Skyscan 1272 device (Bruker microCT) scan settings: tube voltage = 70 kV ube current = 142 A target = tungsten filter =Al 0.5 mm total sample rotation = 180 angular step size = 0.19 exposure time = 1925 ms binning = 2x2 averaging = 8 random movement = 15 voxel size = 4.4 m filename:Schucht_B_perarmata_osteoderm.tif
    0 references
    19 May 2020
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references

    Identifiers

    0 references