Deprecated: $wgMWOAuthSharedUserIDs=false is deprecated, set $wgMWOAuthSharedUserIDs=true, $wgMWOAuthSharedUserSource='local' instead [Called from MediaWiki\HookContainer\HookContainer::run in /var/www/html/w/includes/HookContainer/HookContainer.php at line 135] in /var/www/html/w/includes/Debug/MWDebug.php on line 372
X-ray Computed Tomography Case Study: Triangle and Pentagon Datasets with Various Sizes, Scales, and Noise Levels - MaRDI portal

Deprecated: Use of MediaWiki\Skin\SkinTemplate::injectLegacyMenusIntoPersonalTools was deprecated in Please make sure Skin option menus contains `user-menu` (and possibly `notifications`, `user-interface-preferences`, `user-page`) 1.46. [Called from MediaWiki\Skin\SkinTemplate::getPortletsTemplateData in /var/www/html/w/includes/Skin/SkinTemplate.php at line 691] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of MediaWiki\Skin\BaseTemplate::getPersonalTools was deprecated in 1.46 Call $this->getSkin()->getPersonalToolsForMakeListItem instead (T422975). [Called from Skins\Chameleon\Components\NavbarHorizontal\PersonalTools::getHtml in /var/www/html/w/skins/chameleon/src/Components/NavbarHorizontal/PersonalTools.php at line 66] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

Deprecated: Use of QuickTemplate::(get/html/text/haveData) with parameter `personal_urls` was deprecated in MediaWiki Use content_navigation instead. [Called from MediaWiki\Skin\QuickTemplate::get in /var/www/html/w/includes/Skin/QuickTemplate.php at line 131] in /var/www/html/w/includes/Debug/MWDebug.php on line 372

X-ray Computed Tomography Case Study: Triangle and Pentagon Datasets with Various Sizes, Scales, and Noise Levels (Q6698253)

From MaRDI portal





Dataset published at Zenodo repository.
Language Label Description Also known as
English
X-ray Computed Tomography Case Study: Triangle and Pentagon Datasets with Various Sizes, Scales, and Noise Levels
Dataset published at Zenodo repository.

    Statements

    0 references
    Description Sample information: The dataset consists of two laser-cut objects made from a 6-mm-thick transparent plastic material called acrylate. The objects have triangular and pentagonal shapes, each containing 12 samples with varying sizes. The right-angle edges of the triangular samples range from 2.8 cm to 4.0 cm, while the edges of the pentagonal samples range from 2.5 cm to 3.0 cm. Each scanning session involved different placements of the objects, resulting in variations in rotation and translation. Scanner information The dataset is acquired in the FleX-ray Laboratory, developed by TESCAN-XRE, located at CWI in Amsterdam. The CT scanner consists of a cone-beam microfocus polychromatic X-ray point source, and a 1944x1536 pixel, 14-bit, flat detector panel (Dexela1512NDT). Full details can be found in [Coban 2020]. Scanning geometry A Region-of-Interest (ROI) scanning approach was used to acquire projections with dimensions of 956 X 10 pixels. The source-to-object and detector-to-object distances were both set to 225 mm. Scanning settings A peak voltage of 90 kV was used. An exposure time of 80 ms per projection was applied, and the source spectrum was shaped using filters consisting of 0.1 mm zinc, 0.2 mm copper, and 0.5 mm aluminum. A total of 3601 projections were acquired. To create a dataset with three noise levels, three emission currents were used: 600 A, 300 A, and 100 A. The lower emission current (100 A) produced data with higher noise levels. Finally, 12 groups of projections were acquired for each shape and each noise level, resulting in a total of 48 groups of projections. Reconstruction The script fan_beam_reconstruction.py uses the ASTRA toolbox [Aarle 2015, Aarle 2016] to reconstruct the dataset. It focuses on the middle row of the detector to approximate fan-beam geometry. File name description For example, Triangle_600 represents triangular samples scanned at an emission current of 600 A. Files within that folderlike Triangle_600_1denote individual samples (in this case, the first sample). Research groupThese datasets are produced by the Computational Imaging group at Centrum Wiskunde Informatica (CI-CWI) in Amsterdam, The Netherlands:https://www.cwi.nl/research/groups/computational-imaging Contact details tianyuan.wang@cwi.nl Acknowledgments This work was supported by the European Union H2020-MSCA-ITN-2020 under Grant Agreement Nember 956172 (xCTing). References [Coban 2020] S. B. Coban, F. Lucka, W. J. Palenstijn, D. Van Loo, and K. J. Batenburg, "Explorative imaging and its implementation at the FleX-ray Laboratory," J. Imaging, vol. 6, no. 18, 2020, doi: 10.3390/jimaging6040018. [Aarle 2015] W. V. Aarle et al., "The ASTRA toolbox: A platform for advanced algo- rithm development in electron tomography," Ultramicroscopy, vol. 157, pp. 3547, 2015. [Aarle 2016] W. V. Aarle et al., "Fast and flexible X-ray tomography using the ASTRA toolbox," Opt. Exp., vol. 24, no. 22, pp. 2512925147, 2016.
    0 references
    17 February 2025
    0 references
    0 references
    0 references
    0 references

    Identifiers

    0 references