The micropolar fluid model for blood flow through a tapered artery with a stenosis
From MaRDI portal
Publication:1939178
DOI10.1007/s10409-008-0185-7zbMath1257.76183OpenAlexW2054862946MaRDI QIDQ1939178
M. A. El Kot, Khaled S. Mekheimer
Publication date: 26 February 2013
Published in: Acta Mechanica Sinica (Search for Journal in Brave)
Full work available at URL: https://doi.org/10.1007/s10409-008-0185-7
Related Items
On the transport of epididymal fluid induced by the metachronal wave of cilia, Analysis of micropolar fluids: existence of potential microflow solutions, nearby global well-posedness, and asymptotic stability, Effects of heat and chemical reaction on Jeffrey fluid model with stenosis, Mathematical analysis of Phan-Thien–Tanner fluid model for blood in arteries, Computational model on pulsatile flow of blood through a tapered arterial stenosis with radially variable viscosity and magnetic field, Biomathematical study of Sutterby fluid model for blood flow in stenosed arteries, Anisotropic micropolar fluids subject to a uniform microtorque: the unstable case, Mathematical modelling of pulsatile flow of blood through catheterized unsymmetric stenosed artery -- effects of tapering angle and slip velocity, Biorheological model on pulsatile flow of blood (K-L fluid) through flexible stenotic tapered blood vessels, A finite micro-rotation material point method for micropolar solid and fluid dynamics with three-dimensional evolving contacts and free surfaces, Mathematical modelling of unsteady flow of a sisko fluid through an anisotropically tapered elastic arteries with time-variant overlapping stenosis, On the filtration of micropolar fluid through a thin pipe, Study of non-Newtonian fluid by K-L model through a non-symmetrical stenosed narrow artery, Effects of magnetic field, porosity, and wall properties for anisotropically elastic multi-stenosis arteries on blood flow characteristics, Transport of micro‐polar fluids in an exponentially diverging tube by means of peristaltic waves of dilating amplitude, Two-phase analysis of blood flow through a stenosed artery with the effects of chemical reaction and radiation, Steady flow of a power law fluid through a tapered non-symmetric stenotic tube, Rigorous derivation of the asymptotic model describing a nonsteady micropolar fluid flow through a thin pipe, Unnamed Item, Asymptotic analysis of the nonsteady micropolar fluid flow through a curved pipe, Computational fluid dynamics analysis of pulsatile blood flow behavior in modelled stenosed vessels with different severities, Mathematical modelling of couple stresses on fluid flow in constricted tapered artery in presence of slip velocity-effects of catheter, Numerical simulation of pulsatile flow of blood in a porous-saturated overlapping stenosed artery, An unsteady flow of magnetic nanoparticles as drug carrier suspended in micropolar fluid through a porous tapered arterial stenosis under non-uniform magnetic field and periodic body acceleration, Power law fluid model for blood flow through a tapered artery with a stenosis, Blood flow analysis in tapered stenosed arteries with pseudoplastic characteristics, On the propulsion of micropolar fluid inside a channel due to ciliary induced metachronal wave, FDM analysis for blood flow through stenosed tapered arteries, Metallic nanoparticles analysis for the blood flow in tapered stenosed arteries: Application in nanomedicines, Two-fluid model for blood flow through a tapered arterial stenosis: effect of non-zero couple stress boundary condition at the interface, Rheological properties of Reiner-Rivlin fluid model for blood flow through tapered artery with stenosis, Theoretical analysis of metallic nanoparticles on blood flow through stenosed artery with permeable walls, An implicit approach to the micropolar fluid model of blood flow under the effect of body acceleration, Influence of Heat and Mass Transfer on Two-Phase Blood Flow with Joule Heating and Variable Viscosity in the Presence of Variable Magnetic Field, Unnamed Item, Numerical investigation of pulsatile blood flow in stenosed artery, Numerical investigation on electro-magneto hydrodynamic flow of Jeffrey nanofluid in an inclined tapered arterial stenosis with variable viscosity, variable magnetic field and periodic body force, Mathematical modelling of time dependent flow of non-Newtonian fluid through unsymmetric stenotic tapered artery: effects of catheter and slip velocity
Cites Work
- An unsteady analysis of non-Newtonian blood flow through tapered arteries with a stenosis
- Mathematical modelling of pulsatile flow of Casson's fluid in arterial stenosis
- Pulsatile flow of Herschel-Bulkley fluid through stenosed arteries -- a mathematical model
- Numerical solution to the flow of a micropolar fluid between porous walls of different permeability
- Suspension model for blood flow through stenotic arteries with a cell-free plasma layer
- Mathematical modelling of three-dimensional flow through an asymmetric arterial stenosis
- Pulsatile flow of blood through a stenosed porous medium under periodic body acceleration
- Two-dimensional blood flow through tapered arteries under stenotic conditions
- Peristaltic pumping of a micropolar fluid in a tube
- Modeling of arterial stenosis and its applications to blood diseases
- A numerical simulation of viscous flows in collapsible tubes with stenoses
- Effect of body acceleration on unsteady pulsatile flow of non-Newtonian fluid through a stenosed artery
- A power-law model of blood flow through a tapered overlapping stenosed artery
- Unnamed Item
- Unnamed Item